Solvent-based acrylic paint with the addition of pigments, binders, dispersing agents and inert mineral fillers.
| Technical data (requirements) | Minimum | Maximum |
|---|---|---|
| Consistency (UK) | 80 | 95 |
| Specific mass (g/cm³) | 1,35 | |
| Drying time (minutes) | 20 | |
| Abrasion resistance | 80 | |
| Gloss at 60º | 15 |
• Always store in a covered and cool place;
• Maximum static stacking: 3 buckets.
• Flammable product;
• Always use PPE, safety glasses and gloves;
• Consult MSDS and inform all procedures to the application team.

Check application conditions such as ambient temperature, floor temperature, dew point table, curing conditions and floor cleanliness.
Shake before application, if necessary, add a maximum of 5% Vimaster Thinner. Solvent-based paint should be applied with a wet thickness of between 0.3mm to 0.6mm. Add Extra I-B glass sphere (premix system) in a proportion of 200 to 250 g/liter of paint, to improve abrasion resistance and ensure residual retro reflectance.
To obtain good retro reflectance, it is recommended to add 400 g/m² of Super II-A and Master II-C spheres (single or double spray).
This paint has high durability. With add Vimaster glass spheres, it becomes a retroreflective system, increasing lanes night visibility and promoting road safety. For more details regarding the application, consult the ABNT NBR 15405 standard (Brazilians standards - Procedures for carrying out the demarcation and evaluation).